Glove Sensor System

NexGen’s Glove Sensor System is an easy to use solution for product designers, ergonomists, safety engineers and health professionals interested in determining pressure or forces when grasping various objects.

The wireless Bluetooth version data is collected via an Android APP and then data is transferred after collection to TS10 software. The USB version provides real-time data capture and display with TS10.

Customers can select the calibration range such as 5-10 psi or 0-30 psi etc. Gloves can also be ordered with higher ranges of 60 and 100 psi.

Benefits

Teflon coated for excellent rub resistance, greater durability and sensitivity than other electronic sensors, and they are completely immune to electronic interference and totally waterproof.

Specifications

Technology: Piezoresistive fabric
Pressure Range: 0 – 30, 60 or 100 psi (0 - 2.1, 4.2 or 7 kg/cm2)
Sensing Points Per Glove: 80
Transmission Type: Bluetooth or USB
Scan Speed: Up to 50 Hz
Glove Sizes: S, M, L, XL
Sensor Size: 0.313” x 0.313” (7.95 mm x 7.95 mm)
Sensor Thickness: 40 mils (1 mm)
Accuracy: ± 10%
Battery Type: 3.7V Lithium ion rechargeable
Repeatability: ± 4%
Repeatability Error: ± 3%
Non-linearity: ± 0.2%
Battery Life: Approx. 8 hours

Request a Quote

Please fill in the form below and click the Submit Request button to send us your quotation requirements. We will reply via email with pricing and delivery information.

Fields marked with an asterisk (*) are required.